Loading...
Validity of the newly developed 4-item anxiety-scale in patients with an implantable cardioverter defibrillator: A 12-month follow-up study
Denollet,J. ; Pedersen,S.S. ; Warnaars,F.E. ; Habibovic,M.
Denollet,J.
Pedersen,S.S.
Warnaars,F.E.
Habibovic,M.
Abstract
Background: Subclinical anxiety symptoms are associated with risk of impaired mental and physical health status, ventricular tachyarrhythmias and mortality, in patients with an implantable cardioverter defibrillator (ICD). This study evaluates the validity of the brief and new 4-item Anxiety Scale (ANX4) and its predictive value in relation to health status 12-months post ICD implantation. Methods: A total of 288 ICD patients completed the ANX4 questionnaire. Factor analysis was performed to assess the validity of the scale. In a subsample of N = 212 patients, regression analysis was performed to assess questionnaires' predictive value of health status at 12-months follow-up. Results: Analyses of the ANX4 revealed a one-factor structure with a high internal consistency (α = 0.894). The ANX4 correlated significantly with existing generic and disease specific measures of anxiety symptoms STAI-S (r = 0.62), GAD-7 (r = 0.58), HADS-A (r = 0.66) and ICD related concerns (ICDC) (r = 0.44). Baseline anxiety symptoms were associated with lower levels of physical (β = −0.276; p < .001) and mental (β = −0.551; p < .001) health status 12-months post ICD implantation, adjusting for demographic and clinical variables. Conclusions: The 4-item ANX4 shows to be a valid measure of anxiety symptoms in ICD patients and predicts physical and mental health status up to 12 months follow-up. Further studies are warranted to replicate these findings, determine the cut-off score for clinical relevant symptoms, and whether the ANX4 can be used in other populations.
Description
Funding Current work was supported with a VIDI grant (91710393) from the Netherlands Organization for Health Research and Development (ZonMW), The Hague, The Netherlands, to Dr. Susanne S Pedersen and was in part supported by the Dutch Heart Foundation (grant no. 300020002).
Date
2020
Journal Title
Journal ISSN
Volume Title
Publisher
Research Projects
Organizational Units
Journal Issue
Keywords
Anxiety, Assessment, Cardiovascular disease, DEATH, DEPRESSIVE SYMPTOMS, DISTRESS, HEALTH SURVEY, Implantable cardioverter defibrillator, MANAGEMENT, QUALITY-OF-LIFE, Questionnaires, RISK, VALIDATION, VENTRICULAR-ARRHYTHMIAS, SDG 3 - Good Health and Well-being
Citation
Denollet, J, Pedersen, S S, Warnaars, F E & Habibovic, M 2020, 'Validity of the newly developed 4-item anxiety-scale in patients with an implantable cardioverter defibrillator : A 12-month follow-up study', Journal of Psychosomatic Research, vol. 133, 110106. https://doi.org/10.1016/j.jpsychores.2020.110106